What our installations have actually cost.
A standby generator installation is a bigger job than most people expect, and the number surprises people. So here's what ours have run, before you spend time on a quote.
Below is everything that goes into one.
Every property is different β generator size, how far the electrical and gas have to run, ground conditions, and whether your existing service needs work.
But nothing complete comes in under $15,000, and that's true no matter which brand you choose. Our recent projects haven't come in below $18,000 in a long time.
- 01A generator, a service-rated transfer switch, and a pad β the equipment alone is most of the cost.
- 02An ESA permit and an ESA inspection.
- 03Licensed gas work by a certified fitter, pressure tested and certified.
- 04Hydro One coordination β your service comes down and goes back up the same day.
- 05Startup, commissioning, and warranty registration in your name.
- 06Sixty-odd separate items, from the generator down to the last connector.
What's included in an installationA typical job, start to finishSee all 64 items included βΎHide the list β΄
Assessment & Engineering
Master ElectricianDone before a single part is ordered. Get this wrong and everything downstream is wrong.
- 1.01Site attendance and electrical service evaluationIncluded
- 1.02Load assessment and generator sizing to the actual serviceIncluded
- 1.03Transfer switch selection β service-rated vs. non-service-ratedIncluded
- 1.04Generator siting to code clearances: windows, doors, vents, gas meter, property lineIncluded
- 1.05Fuel source verification and supply capacity checkIncluded
- 1.06Conduit routing, run lengths, and cable sizingIncluded
- 1.07Written scope, exclusions, and fixed-price quotationIncluded
Permits & Coordination
Work you never seeThe part you never see, and the part low quotes rarely include. It happens on the phone, at a desk, and in a truck. The ESA permit is not paperwork for its own sake β without it, Hydro One will not coordinate the service work.
- 2.01ESA notification and permit applicationIncluded
- 2.02Design drawing prepared and submitted where the job requires oneWhen required
- 2.03Hydro One coordination where the service is disconnected or alteredIncluded
- 2.04Licensed gas contractor engaged and scheduledIncluded
- 2.05Generator ordered, received, and stagedIncluded
- 2.06Material procurement and pickupIncluded
- 2.07Trade sequencing so the power comes back on the same dayIncluded
Equipment & Materials
Partial listA partial list. The small items are not filler β they are what makes the installation pass inspection.
- 3.01Standby generator, cellular-monitored β Generac, Champion or Briggs & StrattonIncluded
- 3.02AGM starting batteryIncluded
- 3.03Oil filter warmer for cold-weather startingIncluded
- 3.04Generator pad and compacted gravel baseIncluded
- 3.05Service-rated automatic transfer switchIncluded
- 3.06Splitter trough and service reconnection hardwareWhere required
- 3.07Service-entrance cable, armoured cable, and TECK control cableIncluded
- 3.08TECK connectors, split bolts, and terminationsIncluded
- 3.09Ground plate, grounding conductor, and bondingIncluded
- 3.10Conduit, LBs, LRs, expansion joints, connectors, locknuts, bushings, strapsIncluded
- 3.11Backboard and mounting materialsIncluded
- 3.12Concrete anchors, fasteners, and structural hardwareIncluded
- 3.13Anti-oxidant compound, dielectric grease, and torque-sealed terminationsIncluded
- 3.14Wire markers, circuit identification, and as-built labellingIncluded
- 3.15Duct seal, caulking, spray foam, and weatherproofing at every penetrationIncluded
- 3.16Tape, tie wraps, cable lube, sealants, and jobsite consumablesIncluded
Tools & Equipment On Site
Owned, maintained, insured β brought to youNone of this appears on an invoice, and all of it is required. A generator installation is not a job you do out of a tool pouch.
- 4.01Excavation, grading, and plate compaction equipment for the pad baseIncluded
- 4.02Generator cart, rollers, straps, and dollies to set the generatorIncluded
- 4.03Rotary hammers, core drills, and hole saws for wall and foundation penetrationsIncluded
- 4.04Hydraulic knockout sets, benders, and cable pullersIncluded
- 4.05Hydraulic lug crimpers and calibrated torque tools β terminations made to manufacturer specIncluded
- 4.06Test equipment: true-RMS meters, clamp ammeter, insulation resistance testerIncluded
- 4.07Temporary power and lighting so your service can be down and the work can continueIncluded
- 4.08Ladders, staging, laser level, and layout equipmentIncluded
- 4.09Arc-flash PPE, insulated tools, lockout/tagout, and fall protectionIncluded
- 4.10Tarps, vacuums, and site protection for your propertyIncluded
Installation
Licensed electrical + licensed gasTwo trades, one schedule. The service comes down and goes back up the same day.
- 5.01Pad prepared, base compacted, generator set and levelledIncluded
- 5.02Transfer switch mounted and terminatedIncluded
- 5.03Service disconnection, meter rework, and reconnectionIncluded
- 5.04Power and control wiring run, terminated, and every wire labelledIncluded
- 5.05Grounding electrode and bonding installed to codeIncluded
- 5.06Gas piping, regulator, and sediment trap by a licensed gas fitterIncluded
- 5.07Gas line pressure tested and certifiedIncluded
Inspection
Electrical Safety AuthorityAn uninspected generator installation is a problem you inherit at resale, and a conversation you don't want to have with an insurer.
- 6.01ESA inspection β attendance and tripIncluded
- 6.02Certificate of Inspection issued in your nameIncluded
Commissioning & Handover
Factory-trained technicianYour unit is registered and activated the day it is commissioned. That activation date is when your warranty term begins.
- 7.01Startup and commissioning by a factory-trained technicianIncluded
- 7.02Load transfer tested under real conditionsIncluded
- 7.03Exercise schedule set and break-in service explainedIncluded
- 7.04Mobile Link cellular monitoring activated and registeredIncluded
- 7.05Factory warranty registered in your nameIncluded
- 7.06Owner walkthrough, operation training, and documentation packageIncluded
- 7.07Full site cleanup and debris removalIncluded
What Stands Behind It
Carried year-round, not per jobEvery price in this trade also carries the cost of being permitted to do the work legally and being around afterward to stand behind it.
- 8.01ECRA/ESA contractor licensing and annual renewalIncluded
- 8.02Commercial general liability insuranceIncluded
- 8.03WSIB coverage and clearance certificatesIncluded
- 8.04Generac dealer authorization and factory technician certification β an installing dealer and a factory-trained servicing dealer are not the same thingIncluded
- 8.05Ongoing manufacturer training as models and controls changeIncluded
- 8.06Service vehicle, fuel, and stocked parts inventoryIncluded
- 8.07Tool replacement, calibration, and testing equipment certificationIncluded
- 8.08Warranty administration and a phone number that still answers in year sevenIncluded
What a low quote usually leaves off
Not always deliberately. Often the contractor simply isn't set up to do it β an installer who isn't an authorized dealer physically cannot perform some of these.
- Registration and activation completed so your warranty term actually starts
- Warranty registration in your name
- A service-rated transfer switch where the code calls for one
- Licensed gas work with a certified pressure test
- Proper grounding and bonding at the generator
- Cellular monitoring set up and confirmed working
- An authorized dealer nearby β manufacturers require one for warranty repairs, and cover only limited travel to reach you